Skip to main content

Clinical evaluation of marginal fit of uncemented CAD-CAM monolithic zirconia three-unit restorations in anterior areas, using scannable and conventional polyvinyl siloxane impression materials

Abstract

Background

The accuracy of impression techniques determines the marginal fit of fixed prostheses. Marginal accuracy plays a main role in the success and failure of treatments. This in-vivo study evaluated the marginal fit of anterior three-unit monolithic zirconia fixed partial dentures (FPDs) using conventional and scannable polyvinyl siloxane impression materials.

Methods

Ten patients were selected to replace the lateral teeth with a three-unit monolithic zirconia bridge. For each patient, in the first group, an impression was made with a two-step putty-wash technique using scannable polyvinyl siloxane material (BONASCAN; DMP, Greece). In the identical session, as the second group, an impression of conventional putty-wash polyvinyl siloxane was taken (BONASIL A+ Putty; DMP, Greece). The marginal discrepancy was measured through the replicas, which were cut perpendicularly within the buccolingual and mesiodistal directions. An Independent t-test was employed for data analyses (P < 0.05).

Results

The marginal discrepancy in a conventional method for central abutment in mid-buccal, mid-lingual, mid-mesial, and mid-distal was higher than in the scannable method but it was not significant (P > 0.05). Also, the marginal discrepancy for canine abutment in the conventional method was higher than in the scannable method, but it was not significant, either (P > 0.05).

Conclusions

FPDs fabricated from both scannable and conventional impression materials were not superior to each other in marginal fit for both central and canine abutments by evaluation using the replica technique.

Peer Review reports

Background

An essential phase in prosthesis construction is the molding operation, which precisely transfers a patient's soft and hard tissues to the laboratory. The accuracy of impression techniques determines marginal fit, which is the primary purpose of any prosthetic treatment [1,2,3]. The feature of impression materials, not deforming during the setting time, expresses dimensional accuracy. Polyvinylsiloxane, also known as additional silicone, has the least amount of permanent deformation [2]. Two common molding techniques can be mentioned: (1) one-step putty-wash and (2) two-step putty-wash. Putty acts as a tray for light body, and wash can record details because of its good flow [4].

After the introduction of glass ceramics, ceramic materials have been widely used for several decades [5] because of high esthetic demands, chemical stability [6], high biocompatibility, and technological developments [7, 8]. Polycrystalline ceramics such as Aluminum Oxide (Al2O3) and Zirconium dioxide (Zirconia, ZrO2), due to their relatively lower cost, are used more than other ceramics [9]. Several oxides are added to zirconia to stabilize the tetragonal and/or cubic phases. Among other oxides (MgO, CeO,CaO) which are added to pure zirconia, yttrium oxide (Y2O3) is the most common stabilizing oxide, added at a rate of 2–5 molar percentage [10]. It has been decades since the presence of dental computer-aided design (CAD) and computer-aided manufacturing (CAM) in dentistry; a straightforward approach and also the speed of construction can be delineated [11, 12]. Many studies have shown that a digital impression is more acceptable than conventional methods, with recent advances in scanners and increased accuracy and their ability for three-dimensional measurement. This is because of the preference of the dentist and patient and the time that it takes [13]. Two different intraoral and extraoral scanning methods are used to achieve digital models. New intraoral scanning techniques using Laser and LED technology create a 3D quality image of intraoral structures, yet rotating bases are applied in extraoral scanners, which use 3D laser surface technology [14]. These two methods have advantages and disadvantages. Factors such as inadequate access, saliva, and movements during intraoral scanning create errors during digitization. Also, extraoral scanning will affect the prosthesis fit because of deformations such as impression material shrinkage or air bubbles and impacts the accuracy of the stone cast, including an expansion or increased falsity because of using powder to reduce reflection [15]. Instead, with the development of scannable elastomeric impressions, we can scan them without pouring a stone cast. The difference between scannable elastomeric impressions and conventional ones is related to their color, physical characteristics, and brightness of surface material, which are hypothesized to enhance digitization [16].

Among three factors, marginal fit, fracture resistance, and esthetics, considered for the success of ceramic restorations [17], the marginal fit is directly related to impression accuracy. Secondary caries at the crown margin and the inflammation of periodontal tissues may occur because of oral fluids and chemo-mechanical forces owing to sizable marginal discrepancies [18]. A critical measurement for evaluating prosthesis fit is discrepancies between the marginal of abutment teeth and retainers after the prosthesis is seated on the teeth. Molin and Karlson first described the technique used to measure the gap space as the replica technique [15]. Despite the disadvantages of the replica technique, most studies considered it as a reliable method to evaluate the marginal and internal discrepancies [16, 17].

There is an intensive relationship between the accuracy of impression techniques and the marginal fit, it can be also stated that marginal accuracy plays a key role in the success and failure of prosthesis treatments. Not enough studies have addressed the accuracy of scannable impression materials. Hence, this in-vivo study aimed at evaluating the marginal fit of three-unit monolithic zirconia FPDs using conventional and scannable polyvinyl siloxane impression materials. The null hypothesis was that there is no difference between conventional and scannable polyvinyl siloxane impression materials on the marginal fit of monolithic zirconia accuracy.

Methods

Selection and tooth preparation

The Ethical committee approved this study. Among patients referred to the prosthodontics department of the School of Dentistry, ten people were selected for lateral teeth replacement with a three-unit monolithic zirconia bridge. All participants were above 16 years of age. At the beginning of the session, all of the patients completed a written informed consent form. Each person's central and canine teeth were prepared with 2 mm occlusal reduction and 1 mm for axials. A sectioned putty index was used to visualize tooth preparation. A round-end taper diamond bur was utilized for 0.3–0.5 mm radial shoulder margin, the preferred finish line for all-ceramic crowns [19].

Impression methods and scanning

For each patient in the first group, an impression was taken with a two-step putty-wash technique using scannable polyvinyl siloxane material (BONASCAN; DMP, Greece). The resulting molds were SD laser-scanned (3Shape D810; 3Shape). Because of the properties of the scannable impression material, there was no need to use the spray while scanning the mold. In the identical session, out of ten patients, an impression of conventional putty-wash polyvinyl siloxane (BONASIL A+ Putty; DMP, Greece), as the second group, was taken with the same approach (Fig. 1). For ease of scanning the die surface, the second group’s cast was sprayed with scanning spray. The dies were also SD laser-scanned (3ShapeD810; 3Shape). The data obtained from both groups, mold scanned and die scanned, were converted into CAD data and designed in a computer software system (3Shape CAD Design software; 3Shape, Copenhagen, Denmark). Bridges were machined out of the multilayered system of monolithic zirconia (DD cubeX2®ML, Multilayer, Cubic Zirconia System, Dental Direkt, Germany) by the aid of a CAD-CAM machine (Cori Tec 340i; imes-icor GmbH, Eiterfeld, Germany). After milling, they were transferred to the furnace (ATRA, ATRA Factory) and sintered as per the manufacturer’s recommendations.

Fig. 1
figure 1

An impression of conventional putty-wash polyvinyl siloxane (left) and scannable putty-wash polyvinyl siloxane (right)

Clinical evaluation

Then, within the clinical evaluation, one examiner adjusted the tissue surface of the pontics, proximal contacts, margins, occlusal, and contours for both three-unit bridges. Then a specialist checked them for final confirmation. Next, the retainers were filled with BONASCAN light body (BONASCAN; DMP, Greece) and were placed on the abutment teeth. The patients were asked to close their teeth on the cotton roll and keep close until the material was set entirely. This thin layer showed a mismatch between the inner surface of the retainer and the prepared teeth.

Replica technique

Once setting the thin silicone layer, this layer was reinforced by injecting regular body silicone (Elite HD + ; Tray material Regular body-normal set, Zhermack, Italy). After the replica set, it was cut perpendicularly with a number 12 surgical blade to the occlusal surface. It was cut within the buccolingual and mesiodistal directions, in the middle points into four sections mid-buccal, mid-lingual, mid-mesial, and mid-distal. Then they were placed on clay or slab (Fig. 2).

Fig. 2
figure 2

The replica was cut perpendicularly to the occlusal surface into four sections within the buccolingual and mesiodistal directions

Measurement

The thickness of the outer silicone layer of the replica, in the middle of the finish line region, was measured with a microscope at 230× magnification (AM413FIT Dino-Lite Pro; Dino-Lite Electronic Corp) and an analysis software system (DinoCapture 2.0; AnMo Electronics Corp). The measurement software using the ruler tool showed marginal discrepancies. All the measurements were taken by the same operator. After measuring light-body silicone layer thickness, bridges with less average marginal discrepancies were cemented (GC Gold Label, radiopaque glass–ionomer luting and lining cement, GC Corporation, Tokyo, Japan).

Statistical analysis

Data was analyzed using SPSS software, version 22.0 (IBM Corp, Armonk, NY, USA). Kolmogorov–Smirnov and Shapiro–Wilk tests showed that the data was normally distributed, and the variances were homogenous. An independent sample t-test was employed to compare the marginal fit of the two groups of conventional and scannable polyvinyl siloxane impression materials (α = 0.05).

Results

The mean and standard deviations (SD) of marginal discrepancy between the two impression methods are shown in Table 1 and Fig. 3. The mean ± SD marginal discrepancy for both abutments in the conventional impression method in mid-buccal, mid-lingual, mid-mesial, and mid-distal was higher than in the scannable method. However, the marginal discrepancy in the conventional method compared with the scannable method in the central abutment in mid-buccal (P = 0.584), mid-lingual (P = 0.502), mid-mesial (P = 0.152), or mid-distal (P = 0.538) was not significant. Also, the marginal discrepancy in the conventional method compared with the scannable method in canine abutment was not significant either (P = 1.000, 0.921, 0.744, and 0.844 respectively).

Table 1 Mean ± standard deviation (SD) of discrepancy values (µm) in 4 middle points of each abutment
Fig. 3
figure 3

The mean and standard deviations of marginal discrepancy of the two impression methods. C: conventional method, S: Scannable method. B1: central mid buccal, L1: central mid lingual, M1: central mid mesial, D1: central mid distal, B3: canine mid buccal, L3: canine mid lingual, M3: canine mid mesial, D3: canine mid distal

Discussion

This in-vivo study evaluated the marginal fit using conventional and scannable polyvinyl siloxane impression materials. The conventional and scannable polyvinyl siloxane impression materials did not significantly affect marginal fit accuracy.

Because scanning the incisal edges in molding materials and scanning methods are in great level of difficulty [20], the anterior teeth were selected for this study with the help of new impression scannable materials. According to the reports by Holmes and colleagues [21], and Wettstein and colleagues [22], the marginal fit is reflected by the marginal discrepancy. Based on several studies [23,24,25], the replica technique was used to assess the marginal fit to compare the marginal discrepancy between the conventional and scannable polyvinyl siloxane impression materials in the present study. In this study, that marginal discrepancy of both central and canine abutment teeth in the conventional impression method in the four mid-buccal, mid-lingual, mid-mesial, and mid-distal regions was not significantly different from marginal discrepancy obtained from the scannable impression material. Therefore, conventional and scannable polyvinyl siloxane impression materials would not significantly affect marginal fit accuracy.

Many studies assessed the marginal and internal fit of restorations made by digital impressions compared with conventional impressions using the replica technique, and comparable or even higher results were found for digital impression materials [26,27,28,29,30,31].

The gap could be a determinative issue for the long-term integration of a restoration. Although the maximum prosthetic precision for CAD-CAM restorations has not been stated clearly, the range of acceptable, marginal discrepancies was 50–120 µm. This gap can be detected clinically at the margin of a crown and result in multiple errors encountered throughout the crown fabrication step [25]. The replica technique is a reliable and accurate method for evaluating the accuracy of dental restorations, which also allows the quantification of discrepancies on inner surfaces and the marginal edge of the crown [23]. A relative disadvantage of the replica technique is the two-dimensional representation of results. However, compared to other techniques, most studies expressed that verifiable and accurate results were obtained through the replica technique [24, 25].

The morphology of elastomeric impressions facilitates photoconductivity of the IOSs or digitizing physical casts precisely in subgingival preparations and undercut or apical areas. Laboratory scanners cannot register the areas of surfaces beyond the incidence of the light they emit [16]. Besides the advantages mentioned for IOSs [32], factors such as saliva and patient movements that make errors during digitization can be factors for more inclination towards scannable elastomeric materials. In reviewing new elastomeric impression materials on the trueness and precision of dental casts obtained from the direct digitization, GarcĂ­a-MartĂ­nez et al. [16] concluded that scannable impressions of two types of vinyl siloxanether impression materials using a laboratory laser scanner showed more accuracy than conventional elastomeric materials.

Several studies that compared the fitting accuracy of fixed prosthetics produced via digital and conventional impressions [15, 27, 28, 31, 33] showed that frameworks fabricated from digital impressions demonstrated better marginal fit than those fabricated from conventional impressions. In line with our results, several studies [26, 29, 30, 34] showed that crowns produced with intraoral scanning techniques offer a comparable or perhaps higher exactitude of marginal fitting accuracy.

In another study [35], the marginal accuracy of CAD/CAM restorations using different impression systems was compared as follows: group 1 (PVS impression scan), group 2 (stone cast scan), group 3 (Cadent iTero), and group 4 (Lava True Definition). With the aid of an optical comparator on each abutment, the marginal misfit of the zirconia FDPs was evaluated at four points. It was concluded that the marginal gap of all impression techniques was statistically significant and was within the acceptable clinical limit (120 μm).

Ahrberg and colleagues [27] evaluated the fit and efficiency of CAD/CAM-fabricated all-ceramic restorations using silicone replicas. Based on direct and indirect digitalization (a Lava C.O.S and a conventional polyether impression) concluded that a significantly better marginal fit was noted with direct digitalization. Another study [15] evaluating the marginal fit of CAD-CAM frameworks fabricated from an intraoral digital impression compared to conventional impression showed that intraoral digital impression systems were better. In another study [33], circumferential marginal gap measurements, including line angles, compare the marginal fit of crowns fabricated with digital and conventional methods. It was noted that the digital fabrication method provided a far better marginal fit than the conventional method. Furthermore, Syrek and colleagues [31] conducted an in-vivo study to analyze the marginal accuracy of a single ceramic crown based on a digital impression (Lava COS) and a conventional impression and showed that the digital group was significantly better than the conventional group.

Similar to our results, another study [34] showed that digital impression systems allowed the fabrication of fixed prosthetic restorations with similar accuracy as conventional impression methods. Moreover, Abdel-Azim and co-workers [26] used conventional impressions and two intraoral digital scanners to compare the marginal fit of lithium disilicate crowns fabricated with CAD/CAM technology. Both digital and conventional impressions were found to produce crowns with similar marginal accuracy. Also, Boeddinghaus and co-workers [29] concluded that compared with zirconia copings using four different techniques (three different intraoral digital and one conventional impression method), the marginal fit in intraoral and laboratory scans was equal. Also, Rödiger and colleagues [30], in a comparative clinical study of fitting accuracy of zirconia single crowns produced via digital and conventional impressions, noted that intraoral scanning techniques had the same or even higher marginal accuracy, which was consistent with our result.

Akhlaghian and colleagues [36] compared the marginal accuracy of zirconia copings fabricated using an intraoral scanner and three indirect scanning methods for different scanners. It was stated that marginal adaptation of all zirconia copings fabricated with four scanning techniques was within a clinically acceptable range. However, the best digitization method was the extraoral laboratory scanner, and the maximum vertical marginal gap was for intraoral scanning. Rajan and co-workers [37] evaluated the marginal adaptation of zirconia copings fabricated by two CAD-CAM systems (CERAMILL and CEREC -In Lab MC XL), CEREC -In Lab MC XL (68 μm) performed higher marginal discrepancies. Baig and colleagues [38] evaluated the marginal fit of Yttria-stabilized tetragonal zirconia polycrystals (Y-TZP) ceramic crowns compared to IPS Empress II and complete metal crowns fabricated using a digital system. The Cercon system (Y-TZP) demonstrated significantly higher marginal gaps than the other two systems.

Conclusion

Within the limitations of this clinical study, monolithic zirconia FPDs fabricated from both scannable impression materials and conventional impression materials were not superior to each other in marginal accuracy by evaluating with the replica technique.

Availability of data and materials

The datasets generated during and analyzed during the current study are not publicly available since the manuscript has not been accepted yet, but are available from the corresponding author on reasonable request.

References

  1. Jamshidy L, Mozaffari HR, Faraji P, Sharifi R. Accuracy of the one-stage and two-stage impression techniques: a comparative analysis. Int J Dent. 2016;2016:7256496.

    Article  Google Scholar 

  2. Rathee S, Eswaran B, Eswaran M, Prabhu R, Geetha K, Krishna G, et al. A comparison of dimensional accuracy of addition silicone of different consistencies with two different spacer designs: in-vitro study. J Clin Diagn Res. 2014;8(7):ZC38–41.

    Google Scholar 

  3. Vögtlin C, Schulz G, Jäger K, Müller B. Comparing the accuracy of master models based on digital intra-oral scanners with conventional plaster casts. Physics in Medicine. 2016;1:20–6.

    Article  Google Scholar 

  4. Chugh A, Arora A, Singh VP. Accuracy of different putty-wash impression techniques with various spacer thickness. Int J Clin Pediatr Dent. 2012;5(1):33–8.

    Article  Google Scholar 

  5. Hjerppe J, Närhi TO, Vallittu PK, Lassila LV. Surface roughness and the flexural and bend strength of zirconia after different surface treatments. J Prosthet Dent. 2016;116(4):577–83.

    Article  Google Scholar 

  6. Ebeid K, Wille S, Hamdy A, Salah T, El-Etreby A, Kern M. Effect of changes in sintering parameters on monolithic translucent zirconia. Dent Mater. 2014;30(12):e419–24.

    Article  Google Scholar 

  7. Işerı U, Ozkurt Z, Kazazoğlu E, Küçükoğlu D. Influence of grinding procedures on the flexural strength of zirconia ceramics. Braz Dent J. 2010;21(6):528–32.

    Article  Google Scholar 

  8. Sen N, Sermet IB, Cinar S. Effect of coloring and sintering on the translucency and biaxial strength of monolithic zirconia. J Prosthetic Dent. 2018;119(2):308.e1-.e7.

    Article  Google Scholar 

  9. White SN, Miklus VG, McLaren EA, Lang LA, Caputo AA. Flexural strength of a layered zirconia and porcelain dental all-ceramic system. J Prosthet Dent. 2005;94(2):125–31.

    Article  Google Scholar 

  10. Giti R, Abbasi B. The effect of translucency and surface treatment on the flexural strength of aged monolithic zirconia. Int J Dent. 2021;2021:8022430.

    Article  Google Scholar 

  11. Hayama H, Fueki K, Wadachi J, Wakabayashi N. Trueness and precision of digital impressions obtained using an intraoral scanner with different head size in the partially edentulous mandible. J Prosthodont Res. 2018;62(3):347–52.

    Article  Google Scholar 

  12. Nedelcu R, Olsson P, Nyström I, Rydén J, Thor A. Accuracy and precision of 3 intraoral scanners and accuracy of conventional impressions: a novel in vivo analysis method. J Dent. 2018;69:110–8.

    Article  Google Scholar 

  13. Arakida T, Kanazawa M, Iwaki M, Suzuki T, Minakuchi S. Evaluating the influence of ambient light on scanning trueness, precision, and time of intra oral scanner. J Prosthodont Res. 2018;62(3):324–9.

    Article  Google Scholar 

  14. Ryan SJSK, Ghoneima A. Three-dimensional analysis of digital models generated from intraoral, extraoral, and CBCT scanning devices. J Dent Maxillofac Res. 2019;2(4):1–7.

    Google Scholar 

  15. Su T-S, Sun J. Comparison of marginal and internal fit of 3-unit ceramic fixed dental prostheses made with either a conventional or digital impression. J Prosthet Dent. 2016;116(3):362–7.

    Article  Google Scholar 

  16. García-Martínez I, CáceresMonllor D, Solaberrieta E, Ferreiroa A, Pradíes G. Accuracy of digitization obtained from scannable and nonscannable elastomeric impression materials. J Prosthet Dent. 2021;125(2):300–6.

    Article  Google Scholar 

  17. Contrepois M, Soenen A, Bartala M, Laviole O. Marginal adaptation of ceramic crowns: a systematic review. J Prosthet Dent. 2013;110(6):447-54.e10.

    Article  Google Scholar 

  18. Sakornwimon N, Leevailoj C. Clinical marginal fit of zirconia crowns and patients’ preferences for impression techniques using intraoral digital scanner versus polyvinyl siloxane material. J Prosthet Dent. 2017;118(3):386–91.

    Article  Google Scholar 

  19. Al-Dwairi ZN, Al-Hiyasat AS, Aboud H. Standards of teeth preparations for anterior resin bonded all-ceramic crowns in private dental practice in Jordan. J Appl Oral Sci. 2011;19(4):370–7.

    Article  Google Scholar 

  20. Malik J, Rodriguez J, Weisbloom M, Petridis H. Comparison of accuracy between a conventional and two digital intraoral impression techniques. Int J Prosthodont. 2018;31(2):107–13.

    Article  Google Scholar 

  21. Holmes JR, Bayne SC, Holland GA, Sulik WD. Considerations in measurement of marginal fit. J Prosthet Dent. 1989;62(4):405–8.

    Article  Google Scholar 

  22. Wettstein F, Sailer I, Roos M, Hämmerle CH. Clinical study of the internal gaps of zirconia and metal frameworks for fixed partial dentures. Eur J Oral Sci. 2008;116(3):272–9.

    Article  Google Scholar 

  23. Trifković B, Budak I, Todorović A, Hodolic J, Puskar T, Jevremovic D, et al. Application of replica technique and sem in accuracy measurement of ceramic crowns. Meas Sci Rev. 2012;12:90–7.

    Article  Google Scholar 

  24. Laurent M, Scheer P, Dejou J, Laborde G. Clinical evaluation of the marginal fit of cast crowns: validation of the silicone replica method. J Oral Rehabil. 2008;35(2):116–22.

    Article  Google Scholar 

  25. Rahme HY, Tehini GE, Adib SM, Ardo AS, Rifai KT. In vitro evaluation of the “replica technique” in the measurement of the fit of Procera crowns. J Contemp Dent Pract. 2008;9(2):25–32.

    Google Scholar 

  26. Abdel-Azim T, Rogers K, Elathamna E, Zandinejad A, Metz M, Morton D. Comparison of the marginal fit of lithium disilicate crowns fabricated with CAD/CAM technology by using conventional impressions and two intraoral digital scanners. J Prosthet Dent. 2015;114(4):554–9.

    Article  Google Scholar 

  27. Ahrberg D, Lauer HC, Ahrberg M, Weigl P. Evaluation of fit and efficiency of CAD/CAM fabricated all-ceramic restorations based on direct and indirect digitalization: a double-blinded, randomized clinical trial. Clin Oral Investig. 2016;20(2):291–300.

    Article  Google Scholar 

  28. Almeida e Silva JS, Erdelt K, Edelhoff D, Araújo É, Stimmelmayr M, Vieira LC, et al. Marginal and internal fit of four-unit zirconia fixed dental prostheses based on digital and conventional impression techniques. Clin Oral Investig. 2014;18(2):515–23.

    Article  Google Scholar 

  29. Boeddinghaus M, Breloer ES, Rehmann P, Wöstmann B. Accuracy of single-tooth restorations based on intraoral digital and conventional impressions in patients. Clin Oral Investig. 2015;19(8):2027–34.

    Article  Google Scholar 

  30. Rödiger M, Heinitz A, Bürgers R, Rinke S. Fitting accuracy of zirconia single crowns produced via digital and conventional impressions—a clinical comparative study. Clin Oral Invest. 2017;21(2):579–87.

    Article  Google Scholar 

  31. Syrek A, Reich G, Ranftl D, Klein C, Cerny B, Brodesser J. Clinical evaluation of all-ceramic crowns fabricated from intraoral digital impressions based on the principle of active wavefront sampling. J Dent. 2010;38(7):553–9.

    Article  Google Scholar 

  32. Zimmermann M, Mehl A, Mörmann WH, Reich S. Intraoral scanning systems - a current overview. Int J Comput Dent. 2015;18(2):101–29.

    Google Scholar 

  33. Ng J, Ruse D, Wyatt C. A comparison of the marginal fit of crowns fabricated with digital and conventional methods. J Prosthet Dent. 2014;112(3):555–60.

    Article  Google Scholar 

  34. Seelbach P, Brueckel C, Wöstmann B. Accuracy of digital and conventional impression techniques and workflow. Clin Oral Invest. 2013;17(7):1759–64.

    Article  Google Scholar 

  35. Shembesh M, Ali A, Finkelman M, Weber H-P, Zandparsa R. An in vitro comparison of the marginal adaptation accuracy of CAD/CAM restorations using different impression systems. J Prosthodont. 2017;26(7):581–6.

    Article  Google Scholar 

  36. Akhlaghian M, Khaledi A-A, Farzin M, Pardis S. Vertical marginal fit of zirconia copings fabricated with one direct and three indirect digital scanning techniques. J Prosthetic Dent. 2020.

  37. Rajan BN, Jayaraman S, Kandhasamy B, Rajakumaran I. Evaluation of marginal fit and internal adaptation of zirconia copings fabricated by two CAD - CAM systems: an in vitro study. J Indian Prosthodont Soc. 2015;15(2):173–8.

    Article  Google Scholar 

  38. Baig MR, Tan KB, Nicholls JI. Evaluation of the marginal fit of a zirconia ceramic computer-aided machined (CAM) crown system. J Prosthet Dent. 2010;104(4):216–27.

    Article  Google Scholar 

Download references

Acknowledgements

None.

Funding

The study was funded by investigators and did not receive external funding.

Author information

Authors and Affiliations

Authors

Contributions

MHK, BA, ZR, RG, ST Methodology, investigation, writing- original draft preparation, BA, RG, and ZR resources, writing-review and editing, project administration, funding acquisition, formal analysis. All authors have read and approved the final version of the manuscript.

Corresponding author

Correspondence to Benika Abbasi.

Ethics declarations

Ethical approval and consent to participate

The local ethical committee of Shiraz University of Medical Sciences, Shiraz, Iran, evaluated and approved the study protocol (IR.SUMS.DENTAL.REC.1399.174). All methods were performed in accordance with the Declaration of Helsinki. All participants were above 16 years of age and written informed consent was obtained from all subjects.

Consent for publication

Not applicable.

Competing interests

The authors state that they have no financial or non-financial conflicts of interest regarding this research.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Kalantari, M.H., Abbasi, B., Giti, R. et al. Clinical evaluation of marginal fit of uncemented CAD-CAM monolithic zirconia three-unit restorations in anterior areas, using scannable and conventional polyvinyl siloxane impression materials. BMC Oral Health 23, 52 (2023). https://0-doi-org.brum.beds.ac.uk/10.1186/s12903-023-02771-z

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://0-doi-org.brum.beds.ac.uk/10.1186/s12903-023-02771-z

Keywords