Skip to main content

Table 7 Sex Estimation equations based on maxillary sinus and tooth indexes

From: Sex estimation using maxillary sinus volume for Chinese subjects based on cone-beam computed tomography

Independent Variable

Equation

SD

Accuracy

Sensitivity

Specificity

PPV

NPV

Maxillary Sinus

VL cm3

Logit(p)=-1.118 + 0.067VL

0.1071

67.50%

60.00%

75.00%

70.59%

65.22%

VR cm3

Logit(p)=-1.099 + 0.065VR

0.1159

72.50%

65.00%

80.00%

76.47%

69.57%

Tooth [4]

V23 cm3

Logit(p)=-8.497 + 14.118V23

0.7601

77.50%

90.00%

65.00%

72.00%

86.67%

V33 cm3

Logit(p)=-6.003 + 11.367V33

0.5176

77.50%

80.00%

75.00%

76.19%

78.95%

V23 + V33 cm3

Logit(p)=-8.914 + 10.457V23 + 4.923V33

0.8535

77.50%

90.00%

65.00%

72.00%

86.67%

L23 mm

Logit(p)=-12.471 + 1.658L23

0.0014

72.50%

75.00%

70.00%

71.43%

73.68%

L36 mm

Logit(p)=-19.68 + 1.798L36

0.0318

70.00%

70.00%

70.00%

70.00%

70.00%

L23 + L36 mm

Logit(p)=-29.38 + 1.501L23 + 1.657L36

0.4882

65.00%

70.00%

60.00%

63.64%

66.67%

  1. Logit(p) the probability value obtained by the equation, VL the volume of the left maxillary sinus, VR the volume of the right maxillary sinus; sensitivity, the proportion of samples tested as male; specificity, the proportion of samples tested as female, PPV the proportion of samples judged to be male by the test that is actually male, NPV the proportion of samples judged to be female by the test that is actually female