Evaluation of the effects of different sand particles that used in dental implant roughened for osseointegration

Abstract

Background

Successful dental implant treatment is directly related to osseointegration. In achieving osseointegration, the surface property of the implant is of great importance. Sandblasting is the most commonly used basic method for modifying the surface. Many companies use different sand particles for surface roughening and claim their sand is the best. This leads clinicians to mix their minds in product selection. In this study, we tried to find the appropriate sand material by working objectively without praising any brand. We believe that the results of the study will help clinicians choose the right dental implant. In this study, machined-surfaced implants and implants sandblasted with Aluminum oxide (Al2O3), Titanium dioxide (TiO2) and Silicon dioxide (SiO2) were compared via biomechanical testing.

Methods

For the study, four 2 year-old sheep, weighing 45 kilograms (kg), were used. Eight implants (Al2O3, TiO2, and SiO2 sandblasted implants and machined-surfaced implants), each with different surface characteristics, were inserted into the bilateral tibia of each sheep under general anesthesia. Results of the initial Resonance Frequency Analysis (RFA) were recorded just after implant insertion. The sheep were then randomly divided into two groups, each with 2 sheep, to undergo either a 1-month or a 3-month assessment. At the end of the designated evaluation period, RFA and removal torque tests were performed.

Results

Although there were no statistically significant differences between the groups, the implants sandblasted with Al2O3 showed a higher Implant Stability Quotient (ISQ) and removal torque value at the end of the 1st and 3rd month.

Conclusions

In short, the results of the study demonstrate that Aluminum oxide is superior to other sand particles.

Peer Review reports

Background

In recent years, there has been a significant increase in the worldwide usage of dental implants. At present, screws and root-shaped intraosseous implants produced from Titanium aluminium vanadium (TiAIV), an alloy containing 6% aluminum and 4% vanadium, are the most popular [1,2,3]. The clinical success of dental implants is directly related to the osseointegration that takes place after the healing period [4]. The surface property of dental implants is the leading factor affecting osseointegration, and thereby, the success of the implant [5].

Once an implant is produced by the Computer Numerical Control machine, it is cleaned and polished, which is followed by roughening of the surface via application of one or more of the modification techniques [6]. The most common and basic technique used to roughen the surface of a titanium implant is sandblasting, a process involving the injection of hard ceramic particles onto the implant surface. Sprayed particles create deep cleavages via a cutting effect on the implant surface. Roughening is then performed by plucking small filler particles from the surface [7]. The primary materials used in the sandblasting process are Aluminum oxide (Al2O3), Titanium dioxide (TiO2), Silicon dioxide (SiO2), hydroxyapatite powders and silicate glass [8]. Comparisons between polished surface (machine-surfaced) and sandblasted surface implants indicate that there are more bone-to-implant contacts in the latter [9].

The first step in forming the implant surface is sandblasting. Acid etching and subsequent modifications are carried out after the completion of the sandblasting step. It is therefore important that the sandblasting is performed with a suitable sand type. Many companies use different sand particles for surface roughening and claim their sand is the best. This leads clinicians to mix their minds in product selection. In this study, we tried to find the appropriate sand material by working objectively without praising any brand. We believe that the results of the study will help clinicians choose the right dental implant. With that in mind, the aim of this study is to determine the ideal sand particles by comparing the early-term and long-term osseointegration characteristics of implants sand-blasted with Al2O3, TiO2 and SiO2 in an experimental sheep model.

Methods

The study was approved by the Animal Ethics Commission of Ankara University in accordance with the European Union Council Directive. Animals were housed and operated on in the Research and Application Farm of the Veterinary Faculty of Ankara University, and the research was conducted in compliance with the animal research guidelines of the Veterinary Faculty, Ankara University. Four female sheep, at 2 years of age and weighing 45 kilograms (kg), were used in the study. The animals were monitored for 1 week and fed with a standard diet. Before the surgery, all animals fasted for 24 h.

A total of 64 cylindrical implants, 4.0 mm (mm) in diameter and 10 mm in length, were used in the study. All of the implants were produced by our project partner, Genamer Technology. A total of 16 implants, eight right and eight left, were applied to each sheep. The type of implant was randomly applied.

For the study, three different test groups, each with an average roughness, and one control group were created, as shown below:

  1. Group 1:

    Test group sandblasted with Al2O3

  2. Group 2:

    Test group sandblasted with TiO2

  3. Group 3:

    Test group sandblasted with SiO2

  4. Group 4:

    Control group without sandblasting (Machined)

The average particle size of the sand particles was 180-200 μm. According to their group placement, 2 Al2O3 sandblasted implants, 2 TiO2 sandblasted implants, 2 SiO2 sandblasted implants, and 2 machined implants (control group) were placed into the proximal tibia of the sheep. The same procedure was also applied to the other tibia, resulting in 12 implants being used in the experimental groups and four implants being used in the control group. The aim here was to have the implants placed in the same animal and the same tibia for both the experimental group and the control group (Table 1). For early-stage assessment (1 month), two of the four animals were used, while for late-stage assessment (3 month), the other two animals were used.

Table 1 Types of implants and numbers for each animal

All surgical procedures were performed under sterile conditions with general anesthesia. First, the surgical area was shaved, washed and disinfected with povidone iodine. To further reduce the risk of postoperative infection, the sheep were treated with antibiotics (Iesefs 1 g, Sefriakson Na intramuscularly [IM] [I.E. Ulagay Ilac, Istanbul, Turkey] before the operation, and 1.5 g IM for 5 days after the operation). Xylazine (Rompun, 0.2- 0.5 ml/kg IM., Bayer, Istanbul, Turkey) and diclofenac potassium (dikloran non-steroid anti-inflammatory IM, 1 mg/kg, Bilim Ilac, Istanbul, Turkey) were administered as premedication. General anesthesia was administered using an intravenous (IV) injection of pentobarbital and maintained by isoflurane 3.5% (volume/volume) (Forane, Abbott Laboratories, Rungis Cedex, France), which was administered through an endotracheal tube.

After the animals received general anesthesia, a mid-crestal incision was made in the metaphyseal region of the tibia. After the skin and periosteum was removed, the bone was reached separately. The areas where the implants were to be placed were marked with pointed burs. Then, 10 mm deep implant cavities were prepared using pilot drills with a diameter of 2 mm, followed by a 2.8 mm 2nd drill and lastly, a 3.5 mm final drill. Implants with a diameter of 4.0 mm and a length of 10 mm were placed in the prepared cavities. A total of 16 implants were used (Fig. 1).

Fig. 1
figure 1

Image of prepared implant cavities

The Osstell Mentor device (Integration Diagnostics AB, Göteborg, Sweden) was used to measure the stability of all implants before closing the flap (Fig. 2). The measurements were performed in five directions (anterior, posterior, right, left and above). The mean value was used to determine the final ISQ of each implant. Afterwards, the fascia, muscle layers and skin were sutured. The operation site was sprayed with oxytetracycline HCl (Terramycin Wound Spray), and the legs were splinted to prevent trauma and tibia fractures. Antibiotic and anti-inflammatory drug use was continued for 5 days. After 2 weeks, the splint and the sutures were removed from the skin. During the course of the study, the animals were regularly provided with food and water. The general health status of all experimental animals was monitored during the healing period, and signs of any infection in the wound areas were carefully checked. At the completion of the healing period, there were no problems detected in any of the animals. One month after the operation, two of the experimental animals were sacrificed, and the implants placed on the tibia were uncovered. The stability of the implants was measured based on the Implant Stability Quotient (ISQ) value, using the Osstell Mentor device. Then, the removal torque test was applied. The same measurements were applied to the other two experimental animals 3 months after they had undergone the operation.

Fig. 2
figure 2

Measurement of stability with Osstell Mentor device

The removal torque test was performed after the ISQ values of the implants were measured. To perform the torque tests, the bone was placed in a vise, and the implant pieces were screwed onto the implant. After the probe of the digital torque meter (Mark-10, MGT 12, USA) was secured onto the implant bearing members, the removal force was applied slowly and incrementally in the counterclockwise direction. The process was completed when the implant began to rotate within the bone cavity. The highest torque value recorded on the digital screen at the time of breakage was measured in the form of Ib-in and recorded in the form of newton centimeter (N/cm).

Results

Resonance frequency analysis finding

Table 2 shows the ISQ values of the four main groups constituting the 1-month experimental study. The initial and 1-month ISQ values of the groups were evaluated by the Wilcoxon test.

Table 2 Statistical analysis of initial and last ISQ value in 1 month experimental animals

Regarding the differences between the 1-month and initial ISQ values according to the separate groups, there was no statistically significant increase between the 1-month ISQ values (mean: 58.62 ± 5.39) and the initial ISQ values (mean: 56.12 ± 3.22) in the implant group sandblasted with Al2O3 (p = 0.155); there was no statistically significant increase between the 1-month ISQ values mean: 54.37 ± 7.44) and the initial ISQ values mean: 55.75 ± 4.49) in the implant group sandblasted with TiO2 (p = 0.664); there was no statistically significant increase between the 1-month ISQ values mean: 53.87 ± 6.79) and the initial ISQ values mean: 51.62 ± 6.45) in the implant group sandblasted with SiO2 (p = 0.102); and there was no statistically significant increase between the 1-month ISQ values mean: 53.62 ± 16.91) and the initial ISQ values in the control group (mean: 53.5 ± 5.75) (p = 0.277).

In the 1-month experimental group, the increase in the ISQ values from the initial ISQ measurement to the 1-month ISQ of all experimental groups and the control group was assessed by the Kruskal Wallis test, from which it was found that the change in the ISQ values of all groups was statistically insignificant (p = 0.763). The 1-month ISQ values of these four groups were compared with each other, and no statistically significant difference was found between the groups (p = 0.425).

Table 3 shows the ISQ values of the four groups in the 3-month experimental study. The initial and 3-month ISQ values of the groups were evaluated using the Wilcoxon test, where a statistically significant increase was found between the 3-month ISQ values mean: 62.75 ± 6.43) and the initial ISQ values mean: 55.62 ± 5.65) in the Al2O3 group (p = 0.018); no statistically significant increase between the 3-month ISQ values mean; 57.87 ± 7.18) and the initial ISQ values mean: 58.5 ± 1.77) in the implant group sandblasted with TiO2 (p = 0.61); and no statistically significant increase between the 3-month ISQ values mean: 59.62 ± 3.37) and the initial ISQ values mean: 58.12 ± 3.44) in the implant group sandblasted with SiO2 (p = 0.131). In the control group, a statistically significant increase was observed between the 3-month mean: 58.5 ± 5.04) and the initial ISQ values mean: 54.75 ± 5.03) (p = 0.007).

Table 3 Statistical analysis of initial and 3-month ISQ value

In the 3-month experimental group, the amount of increase from the initial to the 3-month ISQ of all experimental and control groups was assessed using the Kruskal Wallis test, which showed a statistically insignificant change in the ISQ values of all groups (p = 0,037). Binary comparisons were made with the Mann Whitney test, which indicated that the highest ISQ increase occurred in the group sandblasted with Al2O3.

Removal torque test findings

All of the sheep used in the study were subjected to a removal torque test at the end of the follow-up period. Four different implant groups were compared, and the data derived from all groups were evaluated.

In the 1-month experimental group, the differences between the implant groups sandblasted with Al2O3 (mean: 46.11 ± 17.4 N/cm), sandblasted with TiO2 (mean: 37.95 ± 14.1 N/cm), and sandblasted with SiO2 (mean: 40.27 ± 20.93 N/cm) and the control group (mean: 42.75 ± 17.03 N/cm) were evaluated using the Kruskal Walls test. According to the results, there were no statistical differences between the torque values of the groups (p = 0.656) (Table 4).

Table 4 Statistical analysis of 1-month removal torque test data (Newton/cm)

In the 3-month experimental group, the differences between the implant groups sandblasted with Al2O3 (mean: 109.06 ± 33.36 N/cm), sandblasted with TiO2 (mean: 93.79 ± 14.03 N/cm), and sandblasted with SiO2 (mean: 83.19 ± 21.45 N/cm) and the control group (mean: 82.06 ± 21.79 N/cm) were evaluated using the Kruskal Walls test. The results showed no statistically significant differences between the torque values of the groups (p = 0.107) (Table 5).

Table 5 Statistical analysis of 3-month removal torque test data (Newton/cm)

In cases where the p value was close to α, binary comparisons were made with the Mann Whitney test. In the statistical binary comparisons performed on the experimental animals in the 3rd month, the highest torque value was achieved by the implant group sandblasted with Al2O3, followed by the groups sandblasted with TiO2 and SiO2.

In the study, the 1st and 3rd month torque values of all groups were compared using the Mann-Whitney test. For all groups, the torque values obtained at the end of 3 months were higher than the torque values obtained at the end of 1 month (Table 6).

Table 6 Statistical analysis of 1- and 3-month removal torque test data (Newton/cm)

The Spearman test was used to determine whether there was a linear relationship between the ISQ values and the torque values. The results from this test showed that there was no linear relationship between the ISQ values and the torque values for all implant groups (Table 7).

Table 7 Statistical analysis of the correlation between the final ISQ and torque values (Newton/cm)

Discussion

There are many methods available for performing the surface modification of dental implants. Foremost among them are bioactive coating applications, chemical applications, and abrasive blasting of the outer layer [10].

Sandblasting is a basic, simple method commonly used for the surface preparation of dental implants. [11] It accelerates osteoblast attachment, and thereby increases osseointegration [12, 13]. If the sand particles are not completely removed from the implant body, they may cause inflammation. In the study, there were no signs of any inflammation and infection.

In the present sandblasting methods, a small negative charge is formed on the titanium. With this feature added to the surface, osseointegration increases [14]. In a study conducted by Guo et al., titanium plates applied to different groups were sandblasted with Al2O3, and then the static voltage was measured. The results showed the presence of negative static voltage. However, this static voltage decreased over a period of time before becoming stabilized. The amount of this static voltage was reported to be related to environmental factors, such as sandblasting time, sand type, and humidity [14]. This suggests that changing even a small parameter can result in very different surfaces, a fact that should not be overlooked in the creation and development of the surface [15, 16].

Sandblasting not only changes the structure of the surface but also changes the chemistry of the surface and increases the wettability and the potential for early interaction of the implant surface with biological fluids [17, 18].

The most preferred material for dental implants is Al2O3. Regular roughness values are obtained with particles of different sizes, causing the osteoblast behavior to change and bind to the bone [19, 20]. Al2O3 has also been reported to stimulate the flow of calcium from the bone [21].

Other particles used as an alternative to Al2O3 include TiO2, hydroxyapatite powders and silicate glass [22,23,24,25]. The efficacy of TiO2 has been assessed as an alternative to Al2O3 in many studies. For example, in a study involving implants in dogs, it was observed that surfaces sandblasted with TiO2 had more anchoring than the machined surface, although there was no difference in bone-implant contact percentage [26]. This means that histological findings and mechanical test results are not always parallel.

Choi et al. prepared titanium plates that were sandblasted either with bioactive glass particles or with SiO2, as well as unsanded plates. The highest roughness ratio was observed in the SiO2-blasted plates [27]. A roughened titanium surface enhances the adhesion of protein and the differentiation of bone cells [9, 25, 28, 29].

In the present study, the 1-month and 3-month bone healing in the implants sandblasted with Al2O3, TiO2 and SiO2, and non-blasted implants (control) were investigated. There were no statistically significant differences between the groups in primer stabilization measurements. The similarity of the ISQ values may have been due to the design and geometry being the same for the implants used. There were no statistically significant differences between the ISQ values of the implant groups, and the ISQ was found to increase in the 1-month results. However, the final ISQ average value was higher in the group sandblasted with Al2O3 implants.

In the comparison of the 1-month and 3-month removal torque values, the 3-month removal torque values were higher in all groups. This result suggests that osseointegration increased over time, regardless of the character of the implant surface.

Ramp and Jeffcoat [30] measured implant stability with RFA in an animal model and found that implant stability and bone support correlated well with histological measurements. In the present study, there was no correlation between the ISQ values and the removal torque values.

During the course of the study conducted by Nedir et al., two implants, one with an ISQ value of 43 and the other with an ISQ value of 46, were lost. Implants determined to have a high ISQ value in Nedir’s study were reported to have no problems. As a result, implants with ISQ values equal to or higher than 47 were considered stable [31]. According to the values prescribed by Osstell Mentor, implants with an ISQ value of over 65 should be considered successful. Studies have shown that implants with ISQ values below 50 have a high failure rate.

Becker et al. conducted a study where 7 of the 100 implants applied on 76 patients failed. The mean initial ISQ value of all the implants applied in the study was 72,1 [32]. Despite having a mean final ISQ value of 66,6, 7 implants still failed. In the present study, 64 implants were used, and the mean initial ISQ value, measured after the operation, was found to be 55,5. Although there were 6 implants with an ISQ value below 50 in the 1st month, primer stabilization was achieved in all implants, and all implants were osseointegrated at the end of both the 1st and the 3rd months, with no losses.

It has been indicated that ISQ values may change due to bone quality. Approximately 2-3 mm of the implants used in this study were in type I bone, with the remaining 7-8 mm in type IV bone. Consequently, the resulting ISQ values may be lower than the values obtained in other studies. Higher ISQ values could be obtained if the iliac bone of the sheep were used. İliac bone can be used in future studies.

Some experimental studies have reported a correlation between the findings from histological and histomorphometric studies – which are accepted as the gold standard – and RFA findings, while others have stated there to be no correlation. Gehrke et al. noted in their study that implants blasted with titanium dioxide particles or aluminum dioxide particles had a good anchorage, with no difference in bone–implant contact [33].

Removal torque test disrupts the bone-implant contact and does not allow for histological examination. Histological studies will require implants which does not applied removal torque. In this study, the number of animals to be used in the study had to be increased. However, given the animal ethics guidelines, this number was to be minimized. For these reasons, histological studies were not performed in our study and this is the limitation of the study.

Ferguson et al. placed 6 different surface implants in the pelvis area of sheep and compared them in 3 phases. The acute phase in the 2nd week, the early phase in the 4th week, and the continuous phase in the 8th week were all assessed using the removal torque test. Six implants were placed in each pelvic iliac bone. The removal torque test values were found to increase over time [34]. In the present study, the comparison of the values in the 1st and 3rd month removal torque showed that the 3-month extraction torque values were higher in all groups.

It is well-known that the removal torque value is influenced by the macro design of the implants. The test and control implants of different surface properties used in this study had the same design and the same groove properties in macroscopic terms. Although there was no statistically significant difference between the removal torque values of the implant groups in the 1st month results of our study, the removal torque value of the Al2O3 implant group was higher.

Conclusions

In this study, where four different surfaces were compared, the primer stabilization of all groups was measured using the RFA method, and similar ISQ values were obtained. The similarity of primer stabilization may be because the same design and geometry were used for all the implants. Although there was no significant difference between the ISQ and the removal torque values of the implant groups in the 1-month results, higher values were obtained in the Al2O3 sandblasted implant group. Statistical binary comparisons yielded higher values on Al2O3 blasted surfaces, followed by TiO2 sandblasted, SiO2 sandblasted and non-sandblasted surfaces, although there was no significant difference between removal torque values in the 3-month results. No correlation was found between ISQ values and removal torque values in this study. It was even seen that implants with very low ISQ values had high torque. Overall, the results show that aluminum oxide (Al2O3) is superior to other sand particles. Future studies to be conducted on this subject should involve larger numbers of animals and implants, as well as histological measurements.

Abbreviations

Al2O3 :

Aluminum oxide

IM:

Intramusculary

ISQ:

Implant stability quotient

IV:

Intravenous

kg:

kilogram

mm:

millimeter

RFA:

Resonance frequency analysis

SiO2 :

Silicon dioxide

TiAlV:

Titanium Aluminium Vanadium

TiO2 :

Titanium dioxide

References

  1. Anusavice KJ, Shen C, Rawls HR. Phillips’ science of dental materials. 12th ed. Philadelphia: Saunders; 2012.

  2. Hobkirk JA, Watson RM, Searson LJJ. Introducing dental implants. Edinburgh: Churchill Livingstone; 2003.

    Google Scholar 

  3. Hobo S, Ichida E, Garcia LT. Osseointegration and occlusal rehabilitation. 3rd ed. Germany: Quintessence Publishing; 1991.

  4. Brånemark PI. The Osseointegration book: from Calvarium to calcaneus. Berlin: Quintessence; 2005.

  5. Buser D, Schenk RK, Steinemann S, Fiorellini JP, Fox CH, Stich H. Influence of surface characteristics on bone integration of titanium implants. A histomorphometric study in miniature pigs. J Biomed Mater Res. 1991;25(7):889–902.

    Article  PubMed  Google Scholar 

  6. Brunette DM, Tengvall P, Textor M, Thomsen P. Titanium in Medicine. Berlin: Springer; 2001.

  7. Novaes AB Jr, Souza SL, de Oliveira PT, Souza AM. Histomorphometric analysis of the bone-implant contact obtained with 4 different implant surface treatments placed side by side in the dog mandible. Int J Oral Maxillofac Implants. 2002;17(3):377–83.

    PubMed  Google Scholar 

  8. Piattelli M, Scarano A, Paolantonio M, Iezzi G, Petrone G, Piattelli A. Bone response to machined and resorbable blast material titanium implants: an experimental study in rabbits. J Oral Implantol. 2002;28(1):2–8.

    Article  PubMed  Google Scholar 

  9. Mueller WD, Gross U, Fritz T, Voigt C, Fischer P, Berger G, Rogaschewski S, Lange KP. Evaluation of the interface between bone and titanium surfaces being blasted by aluminium oxide or bioceramic particles. Clin Oral Implants Res. 2003;14(3):349–56.

    Article  PubMed  Google Scholar 

  10. Wennerberg A, Albrektsson T. Effects of titanium surface topography on bone integration: a systematic review. Clin Oral Implants Res. 2009;20(Suppl 4):172–84.

    Article  PubMed  Google Scholar 

  11. Yurttutan ME, Kestane R, Keskin A, Dereci O. Biomechanical evaluation of oversized drilling on implant stability - an experimental study in sheep. J Pak Med Assoc. 2016;66(2):147–50.

    PubMed  Google Scholar 

  12. Anselme K. Osteoblast adhesion on biomaterials. Biomaterials. 2000;21(7):667–81.

    Article  PubMed  Google Scholar 

  13. Nishimoto SK, Nishimoto M, Park SW, Lee KM, Kim HS, Koh JT, Ong JL, Liu Y, Yang Y. The effect of titanium surface roughening on protein absorption, cell attachment, and cell spreading. Int J Oral Maxillofac Implants. 2008;23(4):675–80.

    PubMed  Google Scholar 

  14. Guo CY, Matinlinna JP, Tang AT. Effects of surface charges on dental implants: past, present, and future. Int J Biomater. 2012;2012:381535.

    Article  PubMed  PubMed Central  Google Scholar 

  15. Guo CY, ATH T, Matinlinna JP. A novel effect of sandblasting on titanium surface: static charge generation. J Adhes Sci Technol. 2012;26(23):2603–13.

    Article  Google Scholar 

  16. Guo CT, ATH T, Matinlinna JP. Insights into surface treatment methods of titanium dental implants. J Adhes Sci Technol. 2012;26:189–205.

    Article  Google Scholar 

  17. Ban S, Iwaya Y, Kono H, Sato H. Surface modification of titanium by etching in concentrated sulfuric acid. Dent Mater. 2006;22(12):1115–20.

    Article  PubMed  Google Scholar 

  18. Coelho PG, Lemons JE. Physico/chemical characterization and in vivo evaluation of nanothickness bioceramic depositions on alumina-blasted/acid-etched Ti-6Al-4V implant surfaces. J Biomed Mater Res A. 2009;90(2):351–61.

    Article  PubMed  Google Scholar 

  19. Szmukler-Moncler S, Perrin D, Ahossi V, Magnin G, Bernard JP. Biological properties of acid etched titanium implants: effect of sandblasting on bone anchorage. J Biomed Mater Res B Appl Biomater. 2004;68(2):149–59.

    Article  PubMed  Google Scholar 

  20. Kim MJ, Kim CW, Lim YJ, Heo SJ. Microrough titanium surface affects biologic response in MG63 osteoblast-like cells. J Biomed Mater Res A. 2006;79(4):1023–32.

    Article  PubMed  Google Scholar 

  21. Bushinsky DA, Sprague SM, Hallegot P, Girod C, Chabala JM, Levi-Setti R. Effects of aluminum on bone surface ion composition. J Bone Miner Res. 1995;10(12):1988–97.

    Article  PubMed  Google Scholar 

  22. Gotfredsen K, Wennerberg A, Johansson C, Skovgaard LT, Hjorting-Hansen E. Anchorage of TiO2-blasted, HA-coated, and machined implants: an experimental study with rabbits. J Biomed Mater Res. 1995;29(10):1223–31.

    Article  PubMed  Google Scholar 

  23. Ishikawa K, Miyamoto Y, Nagayama M, Asaoka K. Blast coating method: new method of coating titanium surface with hydroxyapatite at room temperature. J Biomed Mater Res. 1997;38(2):129–34.

    Article  PubMed  Google Scholar 

  24. Mustafa K, Wennerberg A, Wroblewski J, Hultenby K, Lopez BS, Arvidson K. Determining optimal surface roughness of TiO(2) blasted titanium implant material for attachment, proliferation and differentiation of cells derived from human mandibular alveolar bone. Clin Oral Implants Res. 2001;12(5):515–25.

    Article  PubMed  Google Scholar 

  25. Ronold HJ, Ellingsen JE. Effect of micro-roughness produced by TiO2 blasting--tensile testing of bone attachment by using coin-shaped implants. Biomaterials. 2002;23(21):4211–9.

    Article  PubMed  Google Scholar 

  26. Gotfredsen K, Nimb L, Hjorting-Hansen E, Jensen JS, Holmen A. Histomorphometric and removal torque analysis for TiO2-blasted titanium implants. An experimental study on dogs. Clin Oral Implants Res. 1992;3(2):77–84.

    Article  PubMed  Google Scholar 

  27. Choi CR, Yu HS, Kim CH, Lee JH, Oh CH, Kim HW, Lee HH. Bone cell responses of titanium blasted with bioactive glass particles. J Biomater Appl. 2010;25(2):99–117.

    Article  PubMed  Google Scholar 

  28. Abron A, Hopfensperger M, Thompson J, Cooper LF. Evaluation of a predictive model for implant surface topography effects on early osseointegration in the rat tibia model. J Prosthet Dent. 2001;85(1):40–6.

    Article  PubMed  Google Scholar 

  29. Sela MN, Badihi L, Rosen G, Steinberg D, Kohavi D. Adsorption of human plasma proteins to modified titanium surfaces. Clin Oral Implants Res. 2007;18(5):630–8.

    Article  PubMed  Google Scholar 

  30. Ramp LC, Jeffcoat RL. Dynamic behavior of implants as a measure of osseointegration. Int J Oral Maxillofac Implants. 2001;16(5):637–45.

    PubMed  Google Scholar 

  31. Nedir R, Bischof M, Szmukler-Moncler S, Bernard JP, Samson J. Predicting osseointegration by means of implant primary stability. Clin Oral Implants Res. 2004;15(5):520–8.

    Article  PubMed  Google Scholar 

  32. Becker W, Becker BE, Hujoel P, Abu Ras Z, Goldstein M, Smidt A. Prospective clinical trial evaluating a new implant system for implant survival, implant stability and radiographic bone changes. Clin Implant Dent Relat Res. 2013;15(1):15–21.

    Article  PubMed  Google Scholar 

  33. Gehrke SA, Ramirez-Fernandez MP, Granero Marin JM, Barbosa Salles M, Del Fabbro M, Calvo Guirado JL. A comparative evaluation between aluminium and titanium dioxide microparticles for blasting the surface titanium dental implants: an experimental study in rabbits. Clin Oral Implants Res. 2016;

  34. Ferguson SJ, Langhoff JD, Voelter K, von Rechenberg B, Scharnweber D, Bierbaum S, Schnabelrauch M, Kautz AR, Frauchiger VM, Mueller TL, et al. Biomechanical comparison of different surface modifications for dental implants. Int J Oral Maxillofac Implants. 2008;23(6):1037–46.

    PubMed  Google Scholar 

Download references

Acknowledgements

We are grateful to the Ministry of Science, Industry and Technology of the Republic of Turkey for supporting the study.

Funding

This thesis was supported by the project titled 000627.STZ.2010-1 by the General Directorate of Science and Technology (SAN-TEZ) of the Ministry of Science, Industry and Technology of the Rebublic of Turkey. The Ministry of Science, Industry and Technology did not play any roles in the design of the study and collection, analysis, and interpretation of data and in writing the manuscript.

Availability of data and materials

This study was produced using data of Mehmet Emre Yurttutan’s (first author) doctoral thesis study. The datasets used and/or analysed during the current study available from the corresponding author on reasonable request.

Author information

Authors and Affiliations

Authors

Contributions

Conceptualization: MEY; Formal Analysis: MEY; Investigation: MEY, AK Methodology: MEY, AK; Project Administration: AK; Writing – Original Draft: MEY; Writing – Review & Editing: MEY, AK. Both authors read and approved the final manuscript.

Corresponding author

Correspondence to Mehmet Emre Yurttutan.

Ethics declarations

Ethics approval and consent to participate

The study was approved by the Animal Ethics Commission of Ankara University in accordance with the European Union Council Directive (Approval number: 2012-20-116). The research was conducted in conformance with the animal research guidelines of the Veterinary Faculty.

Consent for publication

Manuscript does not contain data from any individual person.

Competing interests

The authors declare that they have no competing interests.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Yurttutan, M.E., Keskin, A. Evaluation of the effects of different sand particles that used in dental implant roughened for osseointegration. BMC Oral Health 18, 47 (2018). https://0-doi-org.brum.beds.ac.uk/10.1186/s12903-018-0509-3

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://0-doi-org.brum.beds.ac.uk/10.1186/s12903-018-0509-3

Keywords